Thermoplastic Waterstop for Water, Chemical and Ozone Resistance
Thermoplastic Waterstop for Water, Chemical and Ozone Resistance
Ribbed Centerbulb Waterstop
Ribbed centerbulb is the most versatile type of waterstop available. The centerbulb accommodates lateral, transverse, and shear movement. Ribbed centerbulb waterstop can be used in expansion, construction, and control joints. Click here for more info and CAD details...
Retrofit Waterstop Systems
Retrofit waterstop is designed to provide a fluid-tight seal between existing and new concrete construction. Click here for more info and CAD details...
Dumbbell and Dumbbell Centerbulb Waterstop
Usually used in below grade applications, where limited movement is expected. Click here for more info and CAD details...
Base Seal Waterstop
Ideal for flat pavement jobs such as runways, large containment slabs, etc. Click here for more info and CAD details...
Integrated Cap Systems Waterstop
Designed to replace post-applied joint sealant, and provide a fluid-tight internal seal like a traditional waterstop with a one-step, integrated unit. Click here for more info and CAD details...
Special Waterstop Shapes
Additional shapes are available for special applications. Currently, Earth Shield manufactures a tear web waterstop, designed for large joint movements such as tank foundations. Click here for more info and CAD details...
Earth Shield Thermoplastic Vulcanizate Waterstop is used as a fluid-tight diaphragm, embedded in concrete, across and along the joint, for primary and secondary containment structures. Earth Shield Chemical Resistant Waterstops are resistant to a wide range of oils, solvents, and aggressive chemicals. Alcohol, ketones, glycols, esters, and aqueous solutions of acids, salts, and bases have little effect on Earth Shield Thermoplastic Vulcanizate Waterstop.

Earth Shield TPV Waterstop is NSF Standard 61 Certified for use in drinking water and is made of a recyclable polymer, so it’s good for health and the environment.
www.earthshield.com/nsf_certified_waterstop.html
The superior chemical resistance of Earth Shield Thermoplastic Vulcanizate Waterstop is enhanced by the use of a ribbed centerbulb configuration, which is available in a 4, 6, and 9-inch width. This provides for greater mechanical bonding with the concrete and a barrier against migration of liquid flow around the waterstop. The ribbed centerbulb style also allows for joint movement and may be used in above or below grade applications. Additional shapes are available for retrofit, extreme expansion, stainless steel and base seal applications.

Installation
Install Earth Shield TPV Waterstop in all concrete joints. Waterstop should be centered in, and run the extent of the joint. All changes of directions should be prefabricated (see Shop Made Fittings), leaving only butt-welding for the field. If installing in an expansion joint, keep center bulb unembedded to allow it to accommodate movement as designed. Use #3 hog rings and tie wire to secure waterstop to reinforcing steel to avoid displacement during the concrete pour. Splice straight lengths of waterstop, and Shop Made Fittings to straight lengths, with an ST-10 In Line Waterstop Splicer with the iron temperature set to 410°F to 430°F.
More detailed installation instructions can be found in our Standard 3-part Specifications.
Technical Assistance
Qualified technical assistance is available during any phase of your construction project.
Specifications
Standard 3-part Specifications are available at our website in Microsoft Word and Adobe PDF format, and upon request in printed and a variety of computer word processor formats. Call our Technical Sales Staff for additional help with your specification.
www.earthshield.com/specifications.html
Suggested Proprietary Short Form Guide Specification Section 03150
(Master Format 2004 — 03 15 13)
TPV Chemical Resistant Waterstop
Waterstop indicated in drawings and specifications for contraction (control), expansion and construction joints to be Earth Shield TPV Chemical Resistant Waterstop Part No. #### [Designer insert appropriate part number here] as manufactured by JP Specialties, Inc.; 551 Birch Street, Lake Elsinore, CA 92530; Phone 951-674-6869
1.Thermoplastic Vulcanizate (TPV) Waterstop shall conform to EPA Title 40 CFR Section 265.193. The suitability of the waterstop for a specific application should be determined by specific testing for that particular requirement per ASTM D471. Project-specific certification to be provided by the manufacturer.
2.Thermoplastic Vulcanizate (TPV) Waterstop shall be independently certified for use in potable water per NSF/ANSI Standard 61. Third-party certified documentation to be provided by the manufacturer.
3.No equals or substitutions allowed.
CSI 3-part Long Form in PDF format






























Applications | Product | Specifications | Tech Library
Availability | Contact Us | Home | Search Site
Copyright © 2001 — 2008 David R. Poole, CSI (JP Specialties, Inc)
Earth Shield® is a registered trademark of JP Specialties, Inc.
Phone: 951-674-6869 Toll Free: 888-836-5778