waterstop for extreme temps and aggresSive chemicals

Stainless Steel Waterstop

Earth Shield® Stainless Steel Waterstop can stop even the most corrosive fluids in their tracks, even at severely elevated temperatures. We offer a variety of metals, grades, and gauges. Earth Shield® uses 20-gauge 316 low-carbon steel as its standard alloy, which offers broad-spectrum corrosion resistance to most aggressive media and is virtually unaffected by the deleterious effects of ozone, making it an ideal choice for ozone contactor structures in modern water treatment plants.

Capable of withstanding elevated temperatures and extreme conditions—documented to perform under intense heat and cold exposure. Serves critical applications such as primary and secondary containment, chemical plants, ozone contactor structures, LNG storage facilities, industrial wastewater treatment, and more.

Earth Shield® Stainless Steel Waterstop is available in many standard shapes and sizes, including profiles for new construction and retrofit. All change-of-direction fabrications can be pre-manufactured, leaving only straight butt welding for the field.

Get in touch

Install Earth Shield® Stainless Steel Waterstop in all concrete joints. Waterstop should be centered and run the full extent of the joint. All changes of direction should be prefabricated (see Shop Made Fittings), leaving only butt-welding for the field. Splices in stainless steel waterstops shall be welded using a TIG (recommended) or MIG process utilizing a welding rod to match the stainless (weld rod: 316ELC; diameter — .035 to .045). Repair damaged waterstops by removing damaged portions and patching. Patches shall overlap a minimum of 1 inch onto an undamaged portion of the waterstop. Weld all straight run material edge-to-edge (no overlapping). If installed in an expansion joint, ensure the backside (or open end of the center “V”) is covered completely with tape, and the annulus (between tape and waterstop) is filled with 7/8” diameter backer rod before concrete pour. The tape and backer rod allow the center “V” to remain open, allowing for joint movement. (Tape and backer rod are not necessary for non-moving contraction and construction joints.)

More detailed installation instructions are in our Standard 3-part Specifications.

Stainless Steel Waterstop CAD Details

Property

Test Method

Typical Results

Tensile Strength

ASTM A240

90,000 psi

Elongation in 2” Minimum

ASTM A240

45%

Yield Strength

ASTM A240

45,000 psi

Rockwell B Hardness

ASTM A240

95

High Temperature Resistance

2,552°F

Free Services

The Waterstop Authority Since 1954

  • Complete plan takeoff and waterstop map
  • 3D isometric waterstop details (for every fitting in the print)
  • Fast jobsite delivery
  • Preconstruction meeting for the contractor
  • Exclusive waterstop site pickup and recycling services
  • Waterstop welding certification course for the contractor installing the Earth Shield® waterstop
  • Accredited online and in-office continuing education webinars and seminars for engineers and architects
  • Winner of the 2024 World of Concrete Most Innovative Product Award 

5/5 Customer Rating on Google Business